G240 Gear Flow Meter

Low cost Gear Flow Meter Model G240

Flow range: 250 cc/min to 240 liters/min (0.07 to 63 gpm)
Accuracy (at 30 cP): ± 0.3% of reading over a 100:1 range
Maximum Operating Pressure: 280 or 414 bar (4000 or 6000 psi)
Displacement: 133 cc/rev (8.1 in3/rev)
Weight: 21 kg (46.0 lbs)
Recommend Filtration: 30 micron (475 mesh)
Port Size: 1" NPT or #16 SAE
Fluids: Most non aqueous, hydrocarbon based liquids

Materials of Construction

Body: Stainless steel, type 303
Gears and shafts: Stainless steel, type 17-4
Bearings: All ball bearings, 440C stainless steel
Seals: Viton® "O" rings - standard; Teflon®, Perfluoroelastomer - optional

Transmitter Variations (dependent on model #)

Signal Type

Frequency
Output: 5V pulse, single phase (current sinking, also available)
Resolution: 7000 pulses/liter
Temperature Rating:
Standard: 90°C ; Two Piece High Temp: 155 °C ; Two Piece Ultra High Temp: 225 °C

Quadrature
Output: 5V pulse, two phase
Resolution: 3500 pulses/liter/phase
Linearization: Linearized
Temperature Rating:
Standard: 90°C ; Two Piece High Temp: 155 °C ; Two Piece Ultra High Temp: 225 °C

Voltage
Output:
0-10Vdc 
Resolution: Uni or bidirectional
Linearization: Linearized
Temperature Rating:
Standard: 90°C ; Two Piece High Temp: 155 °C ; Two Piece Ultra High Temp: 225 °C


Current
Output: 0-20mA
Resolution: Uni or bidirectional
Linearization: Linearized
Temperature Rating:
Standard: 90°C ; Two Piece High Temp: 155 °C ; Two Piece Ultra High Temp: 225 °C

Compliance: CE Certified, Ex-proof version available with ATEX/IECEx II 2 G Ex db IIB Tx Gb as well as UL, cUL certification for Class 1, Division 1, Groups C and D, Tx
Maximum temperature rating for ATEX certified transmitters is 130°C

Dimensional Drawing

G240 Illustration

Pressure Drop Curve

G240 Pressure Drop Chart

Library

G240 Typical Applications

Meter Features- Accurate over a 200:1 range- Broader working range reduces the number of flow...
Hydrocarbon refining facilities require accurate flow measurement instruments to safely and...
Precise polymer loading into the fiber matrix ensures adequate coverage, with no waste.  Carbon...
As the operating pressure of hydraulic systems increase, the component test stands need to follow...
The Power Generation industry strives for the highest levels of energy efficiency and the lowest...
Viscous Fuel oil faces a major challenge in its use; namely energy lost in heating it to reduce its...